3KW 5KW Off Grid Solar Inverter 110V
3KW 5KW Off Grid Solar Inverter 110V
3KW 5KW Off Grid Solar Inverter 110V
3KW 5KW Off Grid Solar Inverter 110V
1 / 8
3KW 5KW Off Grid Solar Inverter 110V
3KW 5KW Off Grid Solar Inverter 110V
Dar> Prodotti> Inverter solari> 110V inverter solari> 3KW 5KW Off Grid Solar Inverter 110V

3KW 5KW Off Grid Solar Inverter 110V

$11,300.00   —  $5,600,000.00 /Set
application
Output Power

Deskrizzjoni tal-prodott

Attributi tal-Prodott

Mudell Nru.IGrid MLV 3KW-U

BrandQawwa Easun

Place Of OriginChina

Output TypeSingle

Types OfDc/Ac Inverters

Battery Voltage24VDC

Floating Charge Voltage27VDC

Overcharge Protection31VDC

Solar Charger TypeMPPT

Rated Input Voltage110/120Vac

Ippakkjar u Kunsinna

Unitajiet tal-Bejgħ:
Carton

Inverter solari

Deskrizzjoni tal-prodott

Karatteristiċi Introduzzjoni:
  • Jappoġġja l-batterija tal-aċidu taċ-ċomb u l-konnessjonijiet tal-batterija tal-li-ion
  • B'funzjoni ta 'attivazzjoni doppja meta l-batterija Li-ion tkun rieqda; Jew l-aċċess għall-provvista ta 'enerġija fotovoltajka tal-mains jista' jikkawża l-attivazzjoni tal-batterija Li-ion.
  • Appoġġ għal fażi maqsuma u output tal-mewġ sine pur b'fażi waħda
  • Jappoġġja erba 'livelli ta' vultaġġ differenti ta '100VAC, 105VAC, 110VAC, u 120VAC kull fażi. Jappoġġja żewġ inputs solari u traċċar simultanju ta 'żewġ funzjonijiet ta' kapaċità ta 'ċċarġjar / ġarr ta' enerġija solari.
  • MPPT doppju b'99.9% effiċjenza u kurrent massimu 22A f'ċirkwit wieħed, adattat perfettament għal moduli ta 'enerġija għolja.
  • Funzjoni tal-modalità li tiffranka l-enerġija biex tnaqqas it-telf ta 'enerġija mingħajr tagħbija.
  • 4 modi ta 'ċċarġjar huma disponibbli: solari biss, prijorità tal-mains, prijorità solari, u ċċarġjar ta' mains imħallta / PV.
  • B'żewġ modi ta 'ħruġ ta' bypass ta 'utilità u produzzjoni ta' inverter, b'funzjoni ta 'provvista ta' enerġija bla interruzzjoni.
  • Disinn tad-dijagramma tal-fluss dinamiku tal-iskrin kbir LCD, faċli biex tifhem l-istatus tal-operazzjoni tad-dejta tas-sistema.
  • 3KW OFF OFF GRID SOLAR INVERTER

Easun Power MPPT 3KW 110VAC / 120VAC Off-Grid Solar Inverter 24V Pure Sine Inverter 100A

Off Grid Solar InverterOff Grid Solar InverterOff Grid Solar Inverter

Models
ISolar MLV 3KW-U
AC mode
Rated input voltage
110/120VAC
Input voltage range
(90Vac-140Vac)±2%
Frequency
50Hz/ 60Hz (Auto detection)
Frequency Range
47±0.3Hz ~ 55±0.3Hz (50Hz)/57±0.3Hz ~ 65±0.3Hz (60Hz);
Overload/short circuit protection
Circuit breaker
Efficiency
>96%
Conversion time (bypass and inverter)
10ms (typical)
AC reverse protection
Available
Maximum bypass overload current
40A
Inverter mode
Output voltage waveform
Pure sine wave
Rated output power (VA)
3000W
Rated output power (W)
3000W
Power factor
1
Rated output voltage (Vac)
120VAC
Output voltage error
±5%
Output frequency range (Hz)
50Hz ± 0.3Hz/60Hz ± 0.3Hz
Efficiency
>92%


Overload protection
102% < load <110%) ±10%: report error and turn off the output after5 minutes;
(110% < load < 125%) ± 10%: report error and turn off the output after 10 seconds;
Load >125% ±10%: report error and turn offthe output after 5 seconds;
Peak power
4500VA
Loaded motor capability
2HP
Output short circuit protection
Circuit breaker
Bypass breaker specifications
40A
Rated battery input voltage
24V (Minimum starting voltage 22V)

Battery voltage range
20.0Vdc~33Vdc ± 0.6Vdc (Undervoltage alarm/shutdown voltage/overvoltage alarm
overvoltage recovery... settable on LCD screen)
Power saving mode
Load ≤25W
AC charging
Battery type
Lead acid or lithium battery
Maximum charge current
60A
Charge current error
± 5Adc
Charge voltage range
18.0Vdc~33Vdc
Short circuit protection
Circuit breaker and blown fuse
Circuit breaker specifications
40A
Overcharge protection
Alarm and turn off charging after 1 minute
PV charging
Maximum PV open circuit voltage
100VDC
PV operating voltage range
30-100VDC
MPPT voltage range
30-95VDC
Battery voltage range
18-33VDC
Maximum output power
1600W
PV charging current range (can be set)
60A
Charging short circuit protection
Blown fuse
Wiring protection
Reverse polarity protection
Certified specifications
Certification
CE(IEC/EN62109-1,-2)、ROHS2.0
EMC certification level
EN61000
Operating temperature range
-15°C to 55°C
Storage temperature range
-25°C ~ 60°C
Humidity range
5% to 95% (Conformal coating protection)
Noise
≤60dB
Heat dissipation
Forced air cooling, variable speed of fan
Communication interface
USB/RS485(WiFi/GPRS)/Dry node control
Size (L*W*D)
378mm*280mm*103mm
Weight (kg)
6.2

Model
MLV 5KW-U
AC mode
Rated input voltage
110/120Vac
Input voltage range
(90Vac-140Vac) ±2%
Frequency
50Hz/ 60Hz (auto-sensing)
Frequency Range
47±0.3Hz ~ 55±0.3Hz (50Hz)/57±0.3Hz ~ 65±0.3Hz (60Hz);
Overload/short circuit protection
Breaker
Efficiency
>95%
Conversion time (bypass and inverter)
10ms (Typical value)
AC reverse protection
yes
Maximum bypass overload current
63A
Inverting mode
Output voltage waveform
Pure sine wave
Rated output power(VA)
5000
Rated output power(W)
5000
Power factor
1
Rated output voltage (Vac)
120VAC
Output voltage error
±5%
Output frequency range (Hz)
50Hz ± 0.3Hz/60Hz ± 0.3Hz
Efficiency
>90%

Overload protection
(102%<110%) 5 ±10%: reporting error and turn off the output after minutes; (110%<125%) turn
off the output after 10 seconds; Load>125% ±10%: reporting error and turn off
the output after 5 seconds;
Peak power
10000VA
Loaded motor capacity
4HP
Output short-circuit protection
Breaker
Specification of bypass breaker
63A
Rated battery input voltage
48V (minimum start voltage 44V)
Battery voltage range
40.0Vdc~60Vdc ± 0.6Vdc (undervoltage alarm/turnoff voltage/overvoltage
alarm/overvoltage restoration…settable LCD screen)
Power saving mode
Load ≤25W
AC charge
Battery type
Lead acid or lithium battery
Maximum charge current
40A
Charge current error
± 5Adc
Charge voltage range
40~60Vdc
Short-circuit protection
Breaker and blown fuse
Breaker specification
63A
Overcharge protection
Turn off charge after 1min alarm
Solar charge
Maximum PV opencircuit voltage
500Vdc
PV operation voltage range
120-500Vdc
MPPT voltage range
120-450Vdc
Battery voltage range
40-60Vdc
Maximum output power
5000W
Charge current range of
solar energy (settable)
0-80A
Charge short-circuit protection
Blown fuse
Wiring protection
Inverse wiring protection
Authentication specification
Specification authentication
CE(IEC62109)、RoHs
EMC authentication grade
EN61000
Operation temperature range
-15°C to 55°C
Storage temperature range
-25°C ~ 60°C
Humidity range
5% to 95% (Conformal coating protection)
Noise
≤60dB
Thermal dissipation
Forced cooling with adjustable air speed
Communication interface
USB/RS485 (WiFi/GPRS)/dry node control
Dimension (L*W*D)
426mm*322mm*126mm
Weight (kg)
10.9

Model
MLV 5KW-U
AC mode
Rated input voltage
110/120Vac
Input voltage range
(90Vac-140Vac) ±2%
Frequency
50Hz/ 60Hz (auto-sensing)
Frequency Range
47±0.3Hz ~ 55±0.3Hz (50Hz)/57±0.3Hz ~ 65±0.3Hz (60Hz);
Overload/short circuit protection
Breaker
Efficiency
>95%
Conversion time (bypass and inverter)
10ms (Typical value)
AC reverse protection
yes
Maximum bypass overload current
63A
Inverting mode
Output voltage waveform
Pure sine wave
Rated output power(VA)
5000
Rated output power(W)
5000
Power factor
1
Rated output voltage (Vac)
120VAC
Output voltage error
±5%
Output frequency range (Hz)
50Hz ± 0.3Hz/60Hz ± 0.3Hz
Efficiency
>90%


Overload protection
(102%<110%) 5 ±10%: reporting error and turn off the output after minutes; (110%<125%) turn
off the output after 10 seconds; Load>125% ±10%: reporting error and turn off
the output after 5 seconds;
Peak power
10000VA
Loaded motor capacity
4HP
Output short-circuit protection
Breaker
Specification of bypass breaker
63A
Rated battery input voltage
48V (minimum start voltage 44V)
Battery voltage range
40.0Vdc~60Vdc ± 0.6Vdc (undervoltage alarm/turnoff voltage/overvoltage
alarm/overvoltage restoration…settable LCD screen)
Power saving mode
Load ≤25W
AC charge
Battery type
Lead acid or lithium battery
Maximum charge current
40A
Charge current error
± 5Adc
Charge voltage range
40~60Vdc
Short-circuit protection
Breaker and blown fuse
Breaker specification
63A
Overcharge protection
Turn off charge after 1min alarm
Solar charge
Maximum PV opencircuit voltage
500Vdc
PV operation voltage range
120-500Vdc
MPPT voltage range
120-450Vdc
Battery voltage range
40-60Vdc
Maximum output power
5000W
Charge current range of
solar energy (settable)
0-80A
Charge short-circuit protection
Blown fuse
Wiring protection
Inverse wiring protection
Authentication specification
Specification authentication
CE(IEC62109)、RoHs
EMC authentication grade
EN61000
Operation temperature range
-15°C to 55°C
Storage temperature range
-25°C ~ 60°C
Humidity range
5% to 95% (Conformal coating protection)
Noise
≤60dB
Thermal dissipation
Forced cooling with adjustable air speed
Communication interface
USB/RS485 (WiFi/GPRS)/dry node control
Dimension (L*W*D)
426mm*322mm*126mm
Weight (kg)
10.9




The file is encrypted. Please fill in the following information to continue accessing it

Prodotti sħan

Dar> Prodotti> Inverter solari> 110V inverter solari> 3KW 5KW Off Grid Solar Inverter 110V
Lista tal-Prodotti Relatati
Contacts:Ms. Camille
Contacts:Mr. 方

Copyright © 2024 Easun Power Technology Corp Limited Id-drittijiet kollha riżervati.

Ibgħat Inkjesta
*
*
*

Aħna se nikkuntattjawk immedjatament

Imla aktar informazzjoni sabiex tkun tista 'tagħmel kuntatt miegħek aktar malajr

Dikjarazzjoni tal-Privatezza: Il-privatezza tiegħek hija importanti ħafna għalina. Il-kumpanija tagħna twiegħed li ma tiżvelax l-informazzjoni personali tiegħek lil kwalunkwe espansija mingħajr il-permessi espliċiti tiegħek.

Ibgħat